Products & Solutions

  • Regenerative Grid Simulator
  • Regenerative Grid Simulator
  • Regenerative Grid Simulator
  • Regenerative Grid Simulator
Regenerative Grid Simulator PAS/PFV Series

PAS Series product is developed for renewable energy related applications. It can simulate the various grid conditions and related test standards. Especially the voltage or frequency transient simulation test feature, it is suitable for production, quality verification, research & development. It also builds in with Low Voltage Ride Through Test (LVRT) test function, step mode, and gradual mode programmable capability.

產品諮詢 Inquiry
Preen AC Power Corp.

PAS/PFV Series

PAS Series product is developed for renewable energy related applications. It can simulate the various grid conditions and related test standards. Especially the voltage or frequency transient simulation test feature, it is suitable for production, quality verification, research & development. It also builds in with Low Voltage Ride Through Test (LVRT) test function, step mode, and gradual mode programmable capability.

PFV Series is a new generation of programmable AC power supply, with four quadrant energy feedback function. This unit not only provides power to the EUT, but also sinks the power back to the grid system which is useful for grid tie device testing applications. The maximum output power for PAS series is up to 2000kVA, and the PFV series is up to 200kVA. The output voltage range is 0~300V(L-N) and the standard output frequency is 45~65Hz continuously adjustable (optional 40~70Hz).

  • 4 Quadrant
    Regenerative Function Ideal for EUT with grid tie function
  • Phase Angle
    Phase Angle Adjustment  Capable to simulate phase angle bewteen each phase
  • STEP & RAMP
    STEP and RAMP Features For easy voltage and frequency programming
  • LVRT
    Low Voltage Ride ThroughIdeal for IEEE-1547 pre-compliance test
  • Reliable & Robust
    Comprehensive Protection Including OVP, OCP, OTP, emergency stop,etc.
  • 7 inches
    Intuitive Touch Screen Easy monitoring and control

Regenerative Function

PAS series is a four-quadrant AC power source which is capable to be a power source or sink the power from the EUT back to the grid system with 90% efficiency. It is suitable for PV Inverter test, EV charger test or other grid tie devices test. Build in with Low Voltage Ride Through (LVRT) test graph and it is very suitable for IEEE-1547 or BDEW related standards compliance test.

HVRT and LVRT Function

HVRT and LVRT Function

PAS built in HVRT/LVRT can simulate the situation when the abnormality is ruled out from on the main AC grid. Simulations such as voltage drop, voltage restore or rising time and remaining time can all be programmed.

Three Phase Independent Output Voltage Setting

Three Phase Independent Output Voltage Setting

Independent setting for three phase high/low voltage ride through to simulate voltage drop and surge.

Ideal for Grid Simulation Applications

The PAS series is a grid simulator particularly designed and developed for renewable energy related applications. It has been widely applied for the testing applications of smart inverters, battery charging/discharging, Power Conditioning System (PCS) and Vehicle-to-grid (V2G). The PAS series not only provides power to the EUT, but also sinks the power back to the grid system, which is suitable for grid testing application.

Harmonics Waveform Synthesis Function (Opt.)

Harmonics Waveform Synthesis Function (Opt.)

PAS series' harmonics waveform synthesis function can allow user to program multiplex distorted harmonic waveform of up to 25 steps. It can simply set up voltage and adjust start phase of each step base on fundamental frequency 50Hz or 60Hz.

GRADUAL and STEP Function

GRADUAL and STEP Function

PAS / PFV series have multiple programmable functions to precisely and effectively simulate various power line disturbances such as voltage or frequency ramp up or ramp down, transient and step changes.

PAS Series product is developed for renewable energy related applications. It can simulate the various grid conditions and related test standards. Especially the voltage or frequency transient simulation test feature, it is suitable for production, quality verification, research and development. It also builds in with Low Voltage Ride Through Test (LVRT) test function, step mode and gradual mode programmable capability.

Specifications
  • Output Power

    Three Phase: 30kVA~2000kVA

  • Output Voltage

    0~300V

  • Output Frequency

    45~65Hz (40~70Hz opt.)

  • THD

    ≦ 2% (Resistive Load)

  • Load Regulation

    ≦ 1% (Resistive Load)

  • Efficiency

    ≧ 92% at Max. Power

  • Input Power Factor

    ≧ 0.99 at Max. Power

  • Interfaces
    • Standard:
    • RS-232
    • RS-485
    • Optional:
    • Ethernet
    • GPIB
    • USB
  • PAS has built-in low voltage ride through (LVRT) mode, which can be easily used for simulating the voltage drop test according to different test standards.
  • PAS/PFV equip with energy feedback feature that feeds energy back into the grid system for saving energy and sinking the power from grid tie devices.
  • PAS series is suitable for standard verification. For example: UL1741, IEEE 1547, BDEW and CEI0-16 etc.
  • Three phase independent voltage adjustment is suitable for three phase unbalanced testing or multiple single phase test units. It also equips with phase angle adjustment.
  • Standard RS-232, RS-485 communication interface, optional GPIB, Ethernet and USB.
  • With 7 inches LCD touch screen display, it can display output voltage, current, frequency, active/apparent power, power factor, test information at the same time.
  • More protection mechanism, detect output undervoltage overvoltage, overcurrent, over load,  input undervoltage/overvoltage, over temperature... etc 20 fault conditions and record 255 operation and alarm information for troubleshooting and analysis.
  • STEP or GRADUAL mode programmable memories can be used for simulate abnormal power condition and run in automatically sequences, which allows you to setup different voltage and frequency in each steps for your power simulation requirements.
Model Number Description
  • PAS-F 33030 Regenerative Grid Simulator(30kVA/300V/45-65Hz, Including LVRT Testing)
  • PAS-F 33045 Regenerative Grid Simulator(45kVA/300V/45-65Hz, IncludingLVRT Testing)
  • PAS-F 33060 Regenerative Grid Simulator(60kVA/300V/45-65Hz, IncludingLVRT Testing)
  • PAS-F 33075 Regenerative Grid Simulator(75kVA/300V/45-65Hz, IncludingLVRT Testing)
  • PAS-F 33100 Regenerative Grid Simulator(100kVA/300V/45-65H, IncludingLVRT Testing)
  • PAS-F 33120 Regenerative Grid Simulator(120kVA/300V/45-65Hz, IncludingLVRT Testing)
  • PAS-F 33150 Regenerative Grid Simulator(150kVA/300V/45-65Hz, IncludingLVRT Testing)
  • PAS-F 33200 Regenerative Grid Simulator(200kVA/300V/45-65Hz, IncludingLVRT Testing)
  • PAS-F 33300 Regenerative Grid Simulator(300kVA/300V/45-65Hz, IncludingLVRT Testing)
  • PAS-F 33400 Regenerative Grid Simulator(400kVA/300V/45-65Hz, IncludingLVRT Testing)
  • PAS-F 33600 Regenerative Grid Simulator(600kVA/300V/45-65Hz, IncludingLVRT Testing)
  • PAS-F 33800 Regenerative Grid Simulator(800kVA/300V/45-65Hz, IncludingLVRT Testing)
  • PAS-F 331000 Regenerative Grid Simulator(1000kVA/300V/45-65Hz, IncludingLVRT Testing)
  • PAS-001 Soft Start Function
  • PAS-002 GPIB Interface
  • PAS-003 Ethernet Interface
  • PAS-004 USB Interface
  • PAS-005 Output Frequency 40-70Hz
  • PAS-006 Output Voltage 0-350V(L-N)
  • PFV-33030 High Power Programmable AC Power Source(30kVA/300V/45-65Hz,Including Regenerative Function)
  • PFV-33045 High Power Programmable AC Power Source(45kVA/300V/45-65Hz,Including Regenerative Function)
  • PFV-33060 High Power Programmable AC Power Source(60kVA/300V/45-65Hz, Including Regenerative Function)
  • PFV-33075 High Power Programmable AC Power Source(75kVA/300V/45-65Hz, Including Regenerative Function)
  • PFV-33100 High Power Programmable AC Power Source(100kVA/300V/45-65Hz, Including Regenerative Function)
  • PFV-33120 High Power Programmable AC Power Source(120kVA/300V/45-65Hz, Including Regenerative Function)
  • PFV-33150 High Power Programmable AC Power Source(150kVA/300V/45-65Hz, Including Regenerative Function)
  • PFV-33200 High Power Programmable AC Power Source(200kVA/300V/45-65Hz,Including Regenerative Function)
  • PFV-33300 High Power Programmable AC Power Source(300kVA/300V/45-65Hz, Including Regenerative Function)
  • PFV-33400 High Power Programmable AC Power Source(400kVA/300V/45-65Hz,Including Regenerative Function)
  • PFV-001 Soft Start Function
  • PFV-002 GPIB Interface
  • PFV-003 Ethernet Interface
  • PFV-004 USB Interface
  • PAS Series Regenerative Grid Simulator

  • Electric Vehicle Supply Equipment ATS (EVSE ATS)

Need more help?