Products & Solutions
Smart Inverter ATS
The Smart Inverter ATS is designed according to the specifications of various standards such as IEEE1547.1, EN50530, NB/T32004, CNS15382 and CNS15599., and has built in the test items into the system. The tests include the abnormal voltage and frequency test, synchronization test, open phase test, reconnect test and harmonics test. Preens PV Inverter ATS can test inverter’s input voltage up to 2000Vdc, grid tied voltage up to 600VL-L and output power up to 2000kW. Moreover, all test data are saved in the system for further analysis and comparison.
-
Overviews
-
Specifications
-
Key Features
-
Documentation
-
Videos
Smart Inverter ATS
The Smart Inverter ATS is a photovoltaic automatic test system launched by Preen lately can meet the electrical performance test of relevant grid-connected test standards such as IEEE1547.1, EN50530, NB/T32004, CNS15382 and CNS15599.
High voltage ride through (HVRT) testing is necessary for testing the grid fault capability of power generation plants. It is one of the key test items to test the capability of electric generators to stay connected in short periods of higher electric network voltage.
Smart Inverter test system can meet electrical performance test of relevant grid-connected test standards such as IEEE1547.1 / EN50530 / NB/32004 / CNS15382.
-
DC Output Power
30kW~1800kW
-
DC Output Voltage
0-2000V
-
DC Output Current
0-2500A
-
AC Output Power
30kVA~2000kVA
-
AC Output Voltage
0-300VL-N (Option: 350VL-N)
-
AC Output Frequency
45-65Hz (Option : 40-70Hz)
- Solar Array Simulation (Built-in EN50530 and I-V Curve Formula)
- Static or Dynamic MPPT Simulation
- I-V Curve Simulation
- Precise Voltage and Current Measurement
- Simulate the Grid Voltage and Frequency Changes
- Four-quadrant AC Source for Regenerate and Recycle the Power to the Grid
- LVRT and HVRT Testing Simulation
- Harmonic Simulation Function (Option)
-
Smart Inverter ATS Introduction